4NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN). 6IBP(optional) CH1:SYS, DIA, MAP. It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc. 112.1'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech).
2Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection. 3All-round monitor for adult, pediatric and neonate. 4With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe. 5Finish all operations by keys and knobs. 6Maximum 8-channel waveform synchronous display.
7Display 7-lead ECG waveform on one screen, cascade ECG waveform display. 8Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling. 9Heart rate variability (HRV) analysis function. 10NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data. 11Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
12Drug concentration calculation and titration table functions. 13One-touch printing of trend graph. 14Connect to Central Monitoring System by 3G, Wi-Fi or wired mode. 15AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.16Anti-high frequency surgical unit, defibrillation-proof special leads are n. Lead mode: 3-lead or 5-lead. Lead selection: I, II, III, aVR, aVL, aVF, V. Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV.
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s. Measurement and alarm range: 15~350 bpm. Accuracy: ±1 % or ±1 bpm, whichever is greater. Alarm accuracy: ± 2 bpm.
Measurement and alarm range: -2.0 mV ~ +2.0 mV. Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater. Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2. PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC.
Measurement and alarm range: 0~150 rpm. Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s.
Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes. Measurement period in STAT mode: 5 minutes. Measurement and alarm range: 10 ~ 270 mmHg. Cuff pressure accuracy: ±3 mmHg.
Maximal mean deviation: ±5 mmHg. Maximal standard deviation: 8 mmHg.
Measurement and alarm range: 0 ~ 100%. Measurement and alarm range: 30 ~ 250 bpm. Measurement accuracy: ±2 bpm or ±2%, whichever is greater.
Measurement and alarm range: 0 ~ 50? 0~69 mmHg, 0.1 mmHg.
70~150 mmHg, 0.25 mmHg. 0~40 mm Hg ±2 mm Hg.
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2. Measuring and Alarm Range: -10~300 mmHg. Accuracy: ±2% or 1mmHg, whichever is greater. Safety classification: Class I, type CF defibrillation-proof applied part.
1Adult fingertip SpO2 probe (5-pin). Dimension: 314 mm(L) × 145 mm(W) × 264 mm(H). Food and Drug Administration and state and local regulatory agencies. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE &TUV of Europe. You can get the item in 10-25 days. You pay us what you see on the invoice, i. Or replace item for you free of charge. Contec Medical Systems focusing on research, manufacture and distribution of medical instruments, was founded in 1992 as a high-tech company. At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories. Most of the domestic hospitals are our customers. Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products We sincerely welcome you to become one of our global partners. We are looking forward to establishing a successful business relationship with you. Contec Medical Systems Contact name: Yoki.